       Gush drenchs the tower is commonly used at high temperature waste gas of combustible environment industry is purified reach in organic off-gas treatment, it is now the equipment of commonly used a processing in off-gas treatment equipment. Gush drenchs the tower is handling side of industrial waste gas is the waste gas or steam that will gather through fan group inside inspiratory washer, shed classics fill layer paragraph (gas / the medium) with catalytic fluid, the makings juice that yields waste gas and filler surface flow (catharsis fluid) sufficient contact, with the acid that contains in adsorptive waste gas or alkalescent contamination, depart clean gas and the liquid that are polluted again next, achieve kosher airy goal. But appear easily after gush drenchs the tower uses period of time a few breakdown, for instance nozzle jams, filling jams, demist layer has the state such as ice, if where manages,encounter these trouble?

       1, nozzle jams

    Reason: The liquid inside cistern contains dust and impurity to be caused too much.

    Handle way: Examining cistern to pass filter plate first is deny break with, whether does water pump water inlet install screen pack, screen pack of water pump bottom whether damaged, assume above exists to the problem is repaired in time or be replaced. Whether does examination nozzle have jam, need to ravel nozzle. Nozzle ravels reach installation way: Tear open next window screw to get off first window board, the person is entered next nozzle are torn open by anticlockwise direction inside the tower, open water pump (the water in cistern should be changed for clear water) shut after working dichotomy bell, press nozzle of mount of suitable hour hand next.


    Off-gas treatment equipment

      2, filling jams

    Reason: The dust in waste gas and agglutinant impurity are adherent form in filling ball appearance, for instance spray paint waste gas, burnish waste gas, organic waste gas is waited a moment.

    Handle way: Drench clear lotion is added to reach a few essence of life that wash clean inside tower cistern in gush, drench as brief liquid gush clean. Assume the agglutinant dust of the conglutinate on filling is overmuch, ought to replace filling in time or take wad clean, clean clean filling or be replaced filling outfit goes back. In the future drenchs in gush inside the tower (point to cistern) attend right amount clear lotion and a few to wash clean essence, clear regularly the floater inside cistern. If have heavy bottom material, seasonable Qing Dynasty is drawn out, make sure the Shui Jie inside cistern is not had completely dust or smudgy.

       3, demist layer crosses water

    Reason: Demist filling passes little or it is fan wind force too big, standard of demist layer height does not accord with a program to ask to cause.

    Handle way: Add demist layer filling full, or filling layer (inside the tower) grille board key is low, add demist layer to stuff wad, or adjust fan equipment transducer in order to reduce wind force.

       4, filling piles up

    Reason: Fan wind force is too large, gush drenchs tower norms and fan wind force do not match cause.

    Handle way: Tear open window next screw get off window board, level filling above pressure a grille board or it is a fan equipment transducer reduce wind force.

       5, fan is started after closing again, the water in cistern can flow from overflow mouth

    Reason: Standard of aeriform imports and exports and program of fan wind force do not match, gush drenchs tower program standard and fan do not match.

    Handle way: Fan equipment transducer reduces wind force or be aeriform imports and exports changes big, mediate ball cock to hold probably control water level.